Electrical requirements |
Parameter |
Low range |
High range |
Nominal voltage |
100 VAC |
240 VAC |
Frequency |
50 to 60 Hz |
50 to 60 Hz |
Typical operating
current |
3.61 A |
1.50 A |
Maximum operating
current |
5.16 A |
2.15 A |
Sequential drive
group spin up |
4.27 A |
1.76 A |
Simultaneous drive
spin up |
6.81 A |
2.71 A |
System rating plate
label |
9.0 A |
3.6 A |
Battery data |
Number of batteries |
2 |
Battery type |
Li-ion |
Weight of battery |
0.157 kg (0.346 lb) |
Battery casing |
Pack |
Battery group |
Accumulator |
System hardware specifications |
Chassis |
DSA E2700 controller-drive tray
conforms to the 483 mm
(19.0 in) rack standard |
Power supplies |
Dual redundant, hot pluggable |
Maximum disk drives |
12 x 4 TB, 3.5”, Nearline SAS |
Maximum net capacity |
40964 GB (RAID‑5 configured)) |
DDR2 memory (system RAM) |
4 GB |
Integrated I/O |
2 x 100 Mbps management port;
2 x 1/10 Gigabit Ethernet, copper |
Space requirements |
Front—cooling |
760 mm (30 in) clearance in front
of the cabinet |
Rear—cooling |
610 mm (24 in) clearance behind
the cabinet |
Front of chassis—maintenance |
760 mm (30 in) clearance in front
of the cabinet |
Rear of chassis—maintenance |
610 mm (24 in) clearance behind
the cabinet |